Stopson Italiana delivered 172 Vent Silencers for 4 different sections in a Bahrain based Refinery

A full-package solution aimed at obtaining total sound insulation towards different target parts in an Oil Refinery in Bahrain, which has recently undergone an ambitious modernization program.

 

The project

Stopson Italiana has successfully concluded the delivery of 172 Vent Silencers to be installed among 4 different structural parts of the Oil Refinery in question. The project assists the expansion program that has been taking place since 2018, and it is expected to reach completion prior to the end of 2022.

The Refinery is situated on the island of Sitra, southwest of the capital city Manaba, and produces about 260,000 barrels per day (bpd) of crude oil and 40,000 bpd of low sulfur diesel.

 

The Supply

The project has been carried out according to the following distribution:

  • n. 2 HP Export Steam Silencers;
  • n. 60 PSIG Steam Vent Silencers;
  • n. 110 PSIG Steam Vent Silencers via a second delivery.

And will cover the following areas: 

  • Safety Systems;
  • Boilers;
  • Blow Out and Clean up;
  • Ventilation Systems.

Most of the Silencers have been provided with a removable internal absorptive pack for easy maintenance and clean-up and a removable rain hood. They are all designed to reach a noise target of 82 dB(A) @ 1 m from the silencer.

 

What is a Vent Silencer

A Vent Silencer is a soundproofing device aimed at eradicating the adverse noises produced by gas or steam flow while piping into the atmosphere. The noise in question can be generated as a result of the high-velocity flow through the valve and/or a turbulence created around any impedance in the line that may cause restriction or simply change the flow’s direction.

Each Vent Silencer is able to provide an overall attenuation of the noise level to the required sound pressure level criteria at a certain distance from the silencer. 

At the same time, noise reduction can be attained both using a reactive section to attenuate the low frequencies and absorption mean of the high frequency, normally using a sound-absorbing material.

Stopson Italiana engineers its Vent Silencers in Italy, using special materials not only in accordance with all quality standards but also in line with the client’s specific needs thanks to a careful customer management process.

⟶ For More Information about Stopson’s Italiana Vent Silencers click here.

 

Stopson Italiana supplied 21 vent silencers for PSV and start-up valves as well as for atmospheric blow-down tank to Agios Nikolaos power plant in Greece

A soundproofing comprehensive installation has been recently delivered to assist 826 MW Power Plant (CCGT) at Agios Nikolaos, Greece.

 

Introduction

With a 9HA.02 gas turbine, a steam turbine, and a 109FB turbo generator, the Agios Nikolaos power plant is one of the biggest and most efficient combined-cycle gas turbine (CCGT) power plants in Europe. In these types of power stations, several technological methods are employed to control combustion processes. Among these, the traditional usage of boilers and HRSG, which are commonly likely to damage surrounding and inner environments via harmful noise exposition. In fact, safety valves, start-up valves, blow down and flash tank have the tendency to create a very high noise level while discharging into the atmosphere.

Stopson Italiana has designed a specified soundproofing technique in order to provide a high degree of noise abatement. The equipment is silenced through the implementation of separated and well sized silencers, which tackle the source of noise directly in three different operational parts: the pressure safety valve (PSV), the start-up valve, and the atmospheric blow-down tank.

 

The Supply in details – technical specifications and characteristics

In details, the total supply has been designed in line with the following configuration:

  • 16 vent silencers were designed for PSV, with flow rates ranging from 30 t/h to 300 t/h, temperatures up to 584°C and noise target of 115 dB(A) @ 1 m.
  • 4 vent silencers designed for start-up valve with flow rates ranging from 6 to 260 t/h, temperatures up to 504°C and noise target of 100 dB(A) @ 1 m.
  • 1 vent silencer applied to the atmospheric blow-down tank, performing flow rate 39 t/h, temp. up to 105 °C, 80 dB(A) @ 1m.

 

Stopson Italiana Vent Silencers

  • Safety Valve (PSV)
  • Relief valve (PRV)
  • Control valve
  • Ejector
  • Startup valve
  • Snort-valve
  • Flash and Blowdown Tanks

⟶ For More Information about Stopson Italiana Vent Silencers click HERE.