<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Steam Vent Silencer - Stopson Italiana</title>
	<atom:link href="https://stopson.it/en/tag/steam-vent-silencer/feed/" rel="self" type="application/rss+xml" />
	<link>https://stopson.it/en/</link>
	<description>Il punto di riferimento per l&#039;insonorizzazione industriale nel mondo</description>
	<lastBuildDate>Thu, 20 Mar 2025 18:22:53 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://stopson.it/wp-content/uploads/2025/03/cropped-cropped-favicon_big1-32x32.png</url>
	<title>Steam Vent Silencer - Stopson Italiana</title>
	<link>https://stopson.it/en/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Stopson Italiana supplied Multi-Inlet Steam Vent Silencers for Pulp Mill in Brazil</title>
		<link>https://stopson.it/en/stopson-italiana-supplied-multi-inlet-steam-vent-silencers-for-pulp-mill-in-brazil/</link>
		
		<dc:creator><![CDATA[giango_admin]]></dc:creator>
		<pubDate>Wed, 29 Sep 2021 10:25:38 +0000</pubDate>
				<category><![CDATA[Projects]]></category>
		<category><![CDATA[industrial soundproofing]]></category>
		<category><![CDATA[multi-inlet silencers]]></category>
		<category><![CDATA[pulp mill]]></category>
		<category><![CDATA[soundproofing projects]]></category>
		<category><![CDATA[Steam Vent Silencer]]></category>
		<category><![CDATA[vent silencer]]></category>
		<guid isPermaLink="false">https://stopson.it/2021/09/29/stopson-italiana-supplied-multi-inlet-steam-vent-silencers-for-pulp-mill-in-brazil/</guid>

					<description><![CDATA[<p>Multi-Inlet Silencers capable to handle flow discharge from 5 steam lines took place within one of the largest ongoing projects in Brazil. The goal of the project was to ensure the best soundproofing performances at the maximum optimization ratio to fill all 5 steam lines into a single silencer body, while 3 of them discharging [&#8230;]</p>
<p>The post <a href="https://stopson.it/en/stopson-italiana-supplied-multi-inlet-steam-vent-silencers-for-pulp-mill-in-brazil/">Stopson Italiana supplied Multi-Inlet Steam Vent Silencers for Pulp Mill in Brazil</a> first appeared on <a href="https://stopson.it/en/">Stopson Italiana</a>.</p>]]></description>
										<content:encoded><![CDATA[<h3><em>Multi-Inlet Silencers capable to handle flow discharge from 5 steam lines took place within one of the largest ongoing projects in Brazil.</em></h3>
<p>The goal of the project was to ensure the best soundproofing performances at the maximum optimization ratio to fill all 5 steam lines into a single silencer body, while 3 of them discharging simultaneously. Inlet nozzles were placed each one with its specific diffuser and all of them were then conveyed into the upper absorptive section. This allowed Stopson Italiana to guarantee sound absorption while optimizing silencers’ space occupancy.</p>
<p>The solution – recently delivered – includes the supply of No.2 Steam Vent Silencer featuring the following characteristics:</p>
<ul>
<li>Ø 3250 mm x H 4100 mm, noise abatement of 85 dB (A) at 1 m</li>
<li>Ø 2000 mm x H 820 mm, noise abatement of 85 dB (A) at 15 m</li>
</ul>
<p>As an example, the multi-inlet feature allows the biggest silencer for different discharge conditions:</p>
<ul>
<li>Maximum flow rate 32.5 t/hr at 376°C for low pressure (6.5 barg of design pressure) with 8” inlet</li>
<li>Maximum flow rate 180.1 t/hr at 420°C for medium pressure (17 barg of design pressure) with 12” inlet</li>
<li>Maximum flow rate 262.0 t/hr at 460°C for high pressure (44 barg of design pressure) with 18” inlet</li>
<li>Maximum flow rate 270.0 t/hr at 195°C for medium pressure (19 barg of design pressure) with 12” inlet</li>
</ul>
<p>&nbsp;</p>
<h3>Our offering for Paper Mill application</h3>
<p>Stopson Italiana has a wide range of products for Paper Mill applications, including Air Filtration, Duct Silencer, Acoustic Enclosures and Barriers, Steam Vent Silencers.<br />
Our Vent Silencers are designed to reduce the noise level of exhaust piping to the atmosphere for pressurized gaseous fluids, such as air, vapor, natural gas, nitrogen, oxygen, carbon dioxide, etc. They can be installed downstream any device acting as a link between a container of pressurized gaseous fluid and the atmosphere. The vent silencer can also provide high or low back pressure relief for the system ensuring proper operation.<br />
Vent silencers can be reactive, absorptive or combined type depending on applications and required attenuation, which can reach as much as 75 dB(A).</p>
<p><strong>Typical Applications for vent silencers are:</strong></p>
<ul>
<li>Safety Valve (PSV)</li>
<li>Relief valve (PRV)</li>
<li>Control valve</li>
<li>Ejector</li>
<li>Start up valve</li>
<li>Snort-valve</li>
<li>Flash and Blow Down Tanks</li>
<li>Blow-off</li>
</ul>
<p>Stopson Italiana’s offering for plant Blow-off cleaning does also include additional services and materials as described below:</p>
<ul>
<li>Engineering</li>
<li>Steam blow flange</li>
<li>Spectacle flanges with gaskets</li>
<li>Demi water pumps</li>
<li>Gate and globe valves</li>
<li>Thermocouples</li>
<li>Temperature and Pressure transmitters</li>
<li>Pneumatic target plates inserters</li>
<li>Installation</li>
<li>Blow-off Supervision</li>
</ul>
<p>&nbsp;</p>
<p>See more about our Silencers <a href="https://staging.bforastiere.it/stopson/products/silencers/" target="_blank" rel="noopener">here</a>.</p><p>The post <a href="https://stopson.it/en/stopson-italiana-supplied-multi-inlet-steam-vent-silencers-for-pulp-mill-in-brazil/">Stopson Italiana supplied Multi-Inlet Steam Vent Silencers for Pulp Mill in Brazil</a> first appeared on <a href="https://stopson.it/en/">Stopson Italiana</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>An in-depth Analysis about Industrial Silencers Manufacturing</title>
		<link>https://stopson.it/en/an-in-depth-analysis-about-industrial-silencers-manufacturing/</link>
		
		<dc:creator><![CDATA[giango_admin]]></dc:creator>
		<pubDate>Mon, 21 May 2018 19:59:49 +0000</pubDate>
				<category><![CDATA[Detailed study]]></category>
		<category><![CDATA[Acoustic silencer design]]></category>
		<category><![CDATA[Engine Silencers]]></category>
		<category><![CDATA[Exhaust Silencers]]></category>
		<category><![CDATA[industrial exhaust silencer design]]></category>
		<category><![CDATA[Industrial noise control silencers]]></category>
		<category><![CDATA[industrial silencer manufacturers Italy]]></category>
		<category><![CDATA[Industrial Silencers Italy]]></category>
		<category><![CDATA[Industrial Silencers Manufacturers]]></category>
		<category><![CDATA[Industrial Silencers production]]></category>
		<category><![CDATA[Industrial soundproofing provider]]></category>
		<category><![CDATA[industrial steam silencer]]></category>
		<category><![CDATA[Noise absorption]]></category>
		<category><![CDATA[Noise reduction]]></category>
		<category><![CDATA[Sound Absorption]]></category>
		<category><![CDATA[Steam Silencers]]></category>
		<category><![CDATA[Steam Vent Silencer]]></category>
		<category><![CDATA[Ventilation Silencers Industrial soundproofing]]></category>
		<guid isPermaLink="false">https://stopson.it/2018/05/17/an-in-depth-analysis-about-industrial-silencers-manufacturing/</guid>

					<description><![CDATA[<p>How and what you need to know to soundproof properly your plant Some basics about noise Noise is commonly defined as unwanted sound. A typical noise control problem includes three basic components: the noise source (machines, fans, pumps, processes etc.), the receiver (persons subjected to the noise); and the path (the route the noise travels [&#8230;]</p>
<p>The post <a href="https://stopson.it/en/an-in-depth-analysis-about-industrial-silencers-manufacturing/">An in-depth Analysis about Industrial Silencers Manufacturing</a> first appeared on <a href="https://stopson.it/en/">Stopson Italiana</a>.</p>]]></description>
										<content:encoded><![CDATA[<h2><b><i>How and what you need to know to soundproof properly your plant</i></b></h2>
<h3>Some basics about noise</h3>
<p><span style="font-weight: 400;">Noise is commonly defined as unwanted sound. A typical noise control problem includes three basic components: the </span><i><span style="font-weight: 400;">noise source</span></i><span style="font-weight: 400;"> (machines, fans, pumps, processes etc.), the </span><i><span style="font-weight: 400;">receiver</span></i><span style="font-weight: 400;"> (persons subjected to the noise); and the </span><i><span style="font-weight: 400;">path</span></i><span style="font-weight: 400;"> (the route the noise travels between the source and the receiver indoors or outdoors).</span></p>
<p><span style="font-weight: 400;">Noise can be classified in two different forms: </span><b>airborne</b><span style="font-weight: 400;"> and </span><b>structure-borne</b><span style="font-weight: 400;">.</span></p>
<p><span style="font-weight: 400;">The first one goes from a source to a receiver as a differential in atmospheric pressure, traveling in all directions. </span><b>Structure-borne</b><span style="font-weight: 400;"> instead is unwanted vibration, which is transmitted from a vibrating source to a receiver through a solid material and regenerated as airborne noise. Once the three main elements (source, path and receiver) have been identified, four ways can be adopted to control the noise: absorption, barriers (blocking), damping and vibration isolation. </span></p>
<p><span style="font-weight: 400;">Perhaps the greatest single contribution of unnecessary noise is the lack of proper maintenance and corresponding preventive maintenance intervals. Equipment that is poorly maintained eventually becomes inefficient. One manifestation of inefficiency is noise (misdirected energy), which, ultimately, becomes the subject of replacement. Typical energy wasters and noise producers are:</span></p>
<ul>
<li style="font-weight: 400;"><em><span style="font-weight: 400;">Steam leaks</span></em></li>
<li style="font-weight: 400;"><em><span style="font-weight: 400;">Slipping belts</span></em></li>
<li style="font-weight: 400;"><em><span style="font-weight: 400;">Worn bearings/gears</span></em></li>
<li style="font-weight: 400;"><em><span style="font-weight: 400;">Improperly aligned belts</span></em></li>
<li style="font-weight: 400;"><em><span style="font-weight: 400;">Unbalanced rotating parts</span></em></li>
<li style="font-weight: 400;"><em><span style="font-weight: 400;">Reciprocating striking parts</span></em></li>
<li style="font-weight: 400;"><em><span style="font-weight: 400;">Insufficiently lubricated parts</span></em></li>
<li style="font-weight: 400;"><em><span style="font-weight: 400;">Contact between moving and stationary parts</span></em></li>
<li style="font-weight: 400;"><em><span style="font-weight: 400;">Compressed air leaks</span></em></li>
<li style="font-weight: 400;"><em><span style="font-weight: 400;">Vibrating sheet metal, such as streamlining</span></em></li>
<li style="font-weight: 400;"><em><span style="font-weight: 400;">Improperly adjusted linkages or cams</span></em></li>
</ul>
<p>&nbsp;</p>
<h3>How to choose the most appropriate Steam Vent Silencer provider</h3>
<p><span style="font-weight: 400;">Which are the most relevant data to be considered in order to identify the correct roles within the supply chain of acoustic manufacturers. Understanding all of the factors involved could simplify the selection of the rightest vent silencer for the application required. But first, it’s important to introduce vent and blowdown silencers, reviewing the factors involved in predicting the noise generated by high-pressure vents. </span></p>
<p><span style="font-weight: 400;">Here below a list about the blowdown and vent applications that require silencers:</span></p>
<ul>
<li style="font-weight: 400;"><em><span style="font-weight: 400;">Steam venting in power generation applications </span></em></li>
<li style="font-weight: 400;"><em><span style="font-weight: 400;">Process control and relief valves in industrial applications </span></em></li>
<li style="font-weight: 400;"><em><span style="font-weight: 400;">Pipeline blowdowns and Natural Gas compressor station</span></em></li>
<li style="font-weight: 400;"><em><span style="font-weight: 400;">Blowdown tanks and autoclaves</span></em></li>
<li style="font-weight: 400;"><em><span style="font-weight: 400;">Bypass valves on blowers and compressors</span></em></li>
<li style="font-weight: 400;"><em><span style="font-weight: 400;">Discharge of high-pressure gas to substantially lower pressure environment (atmosphere). </span></em></li>
<li style="font-weight: 400;"><em><span style="font-weight: 400;">Steam ejectors and hogging vents</span></em></li>
</ul>
<p>&nbsp;</p>
<h3>Vent Silencers and their applications</h3>
<figure id="attachment_3740" aria-describedby="caption-attachment-3740" style="width: 385px" class="wp-caption alignleft"><a href="https://staging.bforastiere.it/stopson/wp-content/uploads/2018/05/Vent-Silencers-Manufacturing.jpg"><img fetchpriority="high" decoding="async" class="wp-image-3740" src="https://stopson.it/wp-content/uploads/2025/03/IMG_0949-Copia-e1526552397320.jpg" alt="" width="385" height="515" /></a><figcaption id="caption-attachment-3740" class="wp-caption-text">Stopson Italiana&#8217;s Steam Vent Silencers</figcaption></figure>
<p><span style="font-weight: 400;">The terms “vent silencer” and “blowdown silencer” refer to the relative application for which each one is used. For both of them the design is similar, since we refer to </span><i><span style="font-weight: 400;">vent silencers </span></i><span style="font-weight: 400;">when being used to vent at a constant flow rate, for a period of time. The word silencer is instead referred to as blowdown, when they are blowing down a finite volume of gas starting at a high pressure, and ending at a low pressure over a given time. Vent silencers are sized for constant flow and blowdown silencers are sized for maximum flow.</span></p>
<p><span style="font-weight: 400;">Vent silencers find wide applications in high pressure vents, steam vents, safety relief valve outlets, system blow downs and purge outlets etc. Vent and blowdown noise is a function of upstream pressure and temperature, type of gas being vented, the valve size and type, plus the effect of downstream piping.</span></p>
<p><span style="font-weight: 400;">Stopson Italiana designs and manufactures high quality Vent Silencers that attenuate the high noise produced by the expansion of Gas, Steam or Air at elevated temperatures to atmospheric pressure. </span></p>
<p><span style="font-weight: 400;">When it’s required the installation of a Vent Silencer, here below all the data required in order to obtain a precise offer:</span></p>
<ul>
<li><em><span style="font-weight: 400;">Application (Vent, Blow down, Relief)</span></em></li>
<li><em><span style="font-weight: 400;">Fluid Composition (Steam, Gas, Air)</span></em></li>
<li><em><span style="font-weight: 400;">Molecular Weight or Specific Gravity</span></em></li>
<li><em><span style="font-weight: 400;">Process conditions upstream of valve and units (lb/hr, SCFM, ACFM)</span></em></li>
<li><em><span style="font-weight: 400;">Temperature Pressure (P1)</span></em></li>
<li><em><span style="font-weight: 400;">Atmospheric pressure ( Pa ) / Temperature (T2)</span></em></li>
<li><em><span style="font-weight: 400;">Line size between valve and silencer</span></em></li>
<li><em><span style="font-weight: 400;">Line size from silencer discharge</span></em></li>
<li><em><span style="font-weight: 400;">Attenuation required (silencer performance)</span></em></li>
<li><em><span style="font-weight: 400;">Allowable pressure drop</span></em></li>
</ul>
<h3></h3>
<p>&nbsp;</p>
<h3>Noise Generated by High-Pressure Vents</h3>
<p><span style="font-weight: 400;">Over the years, there has been a good deal of work done in the field of predicting the noise generated by the high-pressure venting of gases.</span></p>
<h4><b>Factors Influencing Noise Generated by High-Pressure Vents:</b></h4>
<ul>
<li style="font-weight: 400;"><span style="font-weight: 400;">Mass flow – the higher the mass flow, the noisier it becomes.</span></li>
<li style="font-weight: 400;"><span style="font-weight: 400;">The type of gas and its molecular weight/specific gravity – lighter gases are noisier. </span></li>
<li style="font-weight: 400;"><span style="font-weight: 400;">Temperature – higher temperatures result in lighter gas flows, and therefore, higher noise levels.</span></li>
<li style="font-weight: 400;"><span style="font-weight: 400;">Upstream versus downstream pressure – the higher the upstream pressure is relative to downstream pressure, the louder it will be. </span></li>
<li style="font-weight: 400;"><span style="font-weight: 400;">Choke flow (critical flow or sonic flow) – occurs when upstream pressure is roughly two times or greater than downstream pressure, making things much noisier. </span></li>
<li style="font-weight: 400;"><span style="font-weight: 400;">Orifice/opening size of valves, vents, orifice plates, diffusers, etc. – larger diameters result in low frequency noise, while smaller diameters produce higher frequency noise. For instance, diffusers create a shift in the noise spectrum from low frequency (one large vent opening) to high frequency (many smaller openings), which is much easier to attenuate.</span></li>
</ul>
<h4><strong><b>Elements Creating Noise in High-Pressure Venting Systems</b></strong></h4>
<p><span style="font-weight: 400;">The noise at the end of a high-pressure vent pipe is a combination of the noise generated by the high-pressure-drop elements in the system. Essentially, any element that has a high-pressure drop across it or large change in area will create noise and should be included in the noise model to accurately predict overall noise level. </span></p>
<p><span style="font-weight: 400;">The major elements that create noise in high-pressure venting systems are:</span></p>
<ul>
<li style="font-weight: 400;"><span style="font-weight: 400;">Pressure relief and control values – present in virtually all venting systems. </span></li>
<li style="font-weight: 400;"><span style="font-weight: 400;">Vent pipes/nozzles – last element in venting systems, except for those using high-pressure silencer diffusers. </span></li>
<li style="font-weight: 400;"><span style="font-weight: 400;">High-pressure silencer diffusers – when included, usually designed to provide a specific backpressure at the rated flow (sometimes used as fail-safe device). </span></li>
<li style="font-weight: 400;"><span style="font-weight: 400;">Orifice plates – included in many systems as a flow regulator or fail-safe device. </span></li>
<li style="font-weight: 400;"><span style="font-weight: 400;">Enlargers (reducers), headers and abrupt transitions – included in pipe systems for various reasons. Shock Noise Versus Turbulent Mixing. </span></li>
</ul>
<p><strong>There are two phenomena that produce noise in a high-pressure venting system:</strong></p>
<ul>
<li style="font-weight: 400;"><span style="font-weight: 400;">Shock noise – occurs when a choked flow condition exists </span></li>
<li style="font-weight: 400;"><span style="font-weight: 400;">Turbulent mixing – caused by the ripping of the air as the vent gas decelerates to lower velocity, such as the atmosphere. Shock noise is the louder of the two. By adjusting the elements in a piping system it is possible to reduce the shock noise by reducing the magnitude or quantity of choked flow conditions present. Turbulent mixing, on the other hand, is always present, though less of an issue.</span></li>
</ul>
<p><span style="font-weight: 400;">The </span><a href="http://www.sandv.com/home.htm" target="_blank" rel="noopener"><i><span style="font-weight: 400;">Sound Vibration Control Magazine</span></i></a><span style="font-weight: 400;"> released a full report with all the specifications needed (listed in a </span><a href="http://www.sandv.com/downloads/1607pras.pdf" target="_blank" rel="noopener"><span style="font-weight: 400;">Data Sheet</span></a><span style="font-weight: 400;">) in order to proceed with the right purchase of a industrial silencer.</span></p>
<p>&nbsp;</p>
<h3><strong>Industrial silencers: an increase of demand due to a more strict regulation for industries</strong></h3>
<p><span style="font-weight: 400;">An integral part of today&#8217;s industrial process and ventilation systems, industrial fans, blowers, and compressors are leading causes of noise problems. If unaddressed, these issues can lead to health and safety concerns, as well as environmental regulation violation. With the tightening of noise regulations, industrial facilities are required to stay in compliance with regulations. Industrial silencers are typical being used to attenuate noise coming from intake and exhaust systems of industrial facilities. These silencers may be built in limited space.  Inside an industrial area, fan installation is one of the most predominant source. </span></p>
<p><b>Industrial silencers</b><span style="font-weight: 400;"> are engineered to control noise in specific applications, and can alleviate problems in work facilities. With more than 50 years of experience Stopson Italiana soundproofed plants in a broad range of installations, such as:</span></p>
<ul>
<li style="font-weight: 400;"><em><span style="font-weight: 400;">Fan Silencers</span></em></li>
<li style="font-weight: 400;"><em><span style="font-weight: 400;">Duct Silencers</span></em></li>
<li style="font-weight: 400;"><em><span style="font-weight: 400;">Blower Silencers</span></em></li>
<li style="font-weight: 400;"><em><span style="font-weight: 400;">Sound Enclosures</span></em></li>
</ul>
<h4><strong>Gas Turbine Engine Exhaust Silencers</strong></h4>
<p><span style="font-weight: 400;">Silencers are required for almost all installations that particularly include gas turbines and heat recovery steam generators. Our Gas Turbine Exhaust Silencers are especially designed to work in an environment where they are simultaneously exposed to high temperatures and to high velocity turbulent flow.</span></p>
<p><span style="font-weight: 400;">Stopson Italiana provides full custom engineered Inlet Exhaust Silencers for Gas Turbines, DG sets Turbo Compressors and Turbo Blowers. They entail complete solutions in the field of Machinery filtration and acoustic solutions for Gas turbines and compressors.</span></p>
<p><span style="font-weight: 400;">Stopson Italiana Gas Turbine Silencers provide the ideal solution to keep noise at a manageable level, while maintaining the operating efficiency of your turbine intake system.</span></p>
<p><span style="font-weight: 400;">Stopson Italiana designs and manufactures all types of discharge silencers in compliance with the international quality standards. Our discharge silencers are very much effective in reducing the noise for entire systems that receives air for heavy engines &amp; turbine.</span></p>
<p>&nbsp;</p>
<p><strong><em>Stopson Italiana engineers have been designing application-specific products and services for industrial plants and processes since 1965. </em></strong><br />
<strong><em>Each product manufactured is tested and inspected to meet all applicable industry standards in terms of quality, longevity and safety.</em> </strong></p><p>The post <a href="https://stopson.it/en/an-in-depth-analysis-about-industrial-silencers-manufacturing/">An in-depth Analysis about Industrial Silencers Manufacturing</a> first appeared on <a href="https://stopson.it/en/">Stopson Italiana</a>.</p>]]></content:encoded>
					
		
		
			</item>