<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Blow-off Silencers - Stopson Italiana</title>
	<atom:link href="https://stopson.it/en/tag/blow-off-silencers/feed/" rel="self" type="application/rss+xml" />
	<link>https://stopson.it/en/</link>
	<description>Il punto di riferimento per l&#039;insonorizzazione industriale nel mondo</description>
	<lastBuildDate>Thu, 20 Mar 2025 18:22:53 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://stopson.it/wp-content/uploads/2025/03/cropped-cropped-favicon_big1-32x32.png</url>
	<title>Blow-off Silencers - Stopson Italiana</title>
	<link>https://stopson.it/en/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Blow-off Rental Service now available at Stopson Italiana</title>
		<link>https://stopson.it/en/blow-off-rental-service-now-available-at-stopson-italiana/</link>
		
		<dc:creator><![CDATA[giango_admin]]></dc:creator>
		<pubDate>Mon, 28 Feb 2022 07:52:43 +0000</pubDate>
				<category><![CDATA[Detailed study]]></category>
		<category><![CDATA[Acoustic silencer]]></category>
		<category><![CDATA[Blow-off Silencers]]></category>
		<category><![CDATA[industrial soundproofing]]></category>
		<category><![CDATA[noise control]]></category>
		<category><![CDATA[noise mitigation]]></category>
		<category><![CDATA[Noise reduction]]></category>
		<category><![CDATA[silencer rental]]></category>
		<category><![CDATA[soundproofing detailed study]]></category>
		<category><![CDATA[temporary soundproofing]]></category>
		<guid isPermaLink="false">https://stopson.it/2022/02/28/blow-off-rental-service-now-available-at-stopson-italiana/</guid>

					<description><![CDATA[<p>How to solve temporary noise reduction needs linked to Blow-off Operations Nearly any high-pressure gas or steam application has the need to purge or evacuate a system at certain times or as a safety measure. When releasing high-pressure gases into the atmosphere, a large amount of kinetic energy is freed due to the pressure difference. [&#8230;]</p>
<p>The post <a href="https://stopson.it/en/blow-off-rental-service-now-available-at-stopson-italiana/">Blow-off Rental Service now available at Stopson Italiana</a> first appeared on <a href="https://stopson.it/en/">Stopson Italiana</a>.</p>]]></description>
										<content:encoded><![CDATA[<div id="pl-4684" class="panel-layout">
<div id="pg-4684-0" class="panel-grid panel-no-style">
<div id="pgc-4684-0-0" class="panel-grid-cell" data-weight="1">
<div id="panel-4684-0-0-0" class="so-panel widget widget_sow-editor panel-first-child panel-last-child" data-index="0">
<div class="so-widget-sow-editor so-widget-sow-editor-base">
<div class="siteorigin-widget-tinymce textwidget">
<h2>How to solve temporary noise reduction needs linked to Blow-off Operations</h2>
<p>Nearly any high-pressure gas or steam application has the need to purge or evacuate a system at certain times or as a safety measure. When releasing high-pressure gases into the atmosphere, a large amount of kinetic energy is freed due to the pressure difference. The pressure difference causes a dramatic increase in velocity which results in high sound emissions which need to be reduced.</p>
<p>Stopson Italiana Blow-off Silencers are specifically designed to reduce the noise generated by the high differential pressure at the time of a release. The engineering and calculation processes require the following data: medium, mass flow, pressure, and temperature upstream of the valve. The acoustic design covers two main steps: the determination of the non-silenced sound power level and the calculation of the silencer itself.</p>
<p>The sound power level can be transmitted by the valve supplier or inferred by Stopson Italiana using a proprietary framework developed on international standards, and honed by Stopson Italiana&#8217;s scientists.</p>
<h3>What is a Blow-Off Silencer</h3>
<p>The Blow-Off type is a typical expansion and absorption silencer, which is used before the system’s enactment. The principal use is to clean the pipes, removing any solid bodies and residual debris after erection and installation. The expander has a horizontal configuration, located laterally to the body of the silencer, is built with higher thicknesses and usually three metal layers (Case Study: Stopson Italiana’s Blow-off installation in a reconverted paper mill in Italy <a href="https://staging.bforastiere.it/stopson/blow-off-and-steam-vent-silencers-successfully-installed-in-re-converted-paper-mill-in-northern-italy/">here</a>).</p>
<h3>Soundproofing temporary installations</h3>
<p>Profiting from almost sixty years of experience, Stopson Italiana has developed the most efficient silencers with the longest design life. For temporary installations &#8211; like steam purging of pipes before plant start-up or boiler/pipe system maintenance &#8211; suitable blow-off silencers for rent are now available.</p>
<p><strong>Stopson Italiana’s Blow-Off Silencers</strong> cover a wide range of flow rates, pressures, and most common acoustical guarantee targets:</p>
<ul>
<li>20 t/h up to 250 t/h flow capacity</li>
<li>4 bar to 8 bar Inlet pressure</li>
<li>100 dB(A) @ 1m residual SPL or<br />
95 dB(A) @ 10 m or<br />
85 dB(A) @ 30 m</li>
</ul>
<p>In addition, they are designed to withstand typical blow-off temperatures and <strong>feature the following characteristics</strong>:</p>
<ul>
<li><strong>Corten A</strong> body and structure for a longer resistance at high temperature</li>
<li><strong>AISI304</strong> diffuser for clean fluid operations</li>
<li><strong>12”/20” inlet</strong> connections with customized adapters available upon request</li>
<li><strong>T-joint</strong> to avoid larger debris flowing into the diffuser</li>
<li><strong>Supporting legs</strong> 1.5 meters high from the ground</li>
</ul>
<p>Stopson Italiana Blow-Off silencers are <strong>currently available in three models</strong> to cover the entire range of flow rates:</p>
<ul>
<li><strong>SPM 20-70/B:</strong> 20-70 t/h capacity range, from 1.2 bar inlet pressure</li>
<li><strong>SPM 70-120/B:</strong> 70-120 t/h capacity range, from 5 bar inlet pressure</li>
<li><strong>SPM 120-250/B:</strong> 120-250 t/h capacity range, from 8 bar inlet pressure</li>
</ul>
<p><strong>Blow-Off silencers can be also tailor-made</strong> for Sales against project and Customer specifications with flow rates up to 900 t/h. Stopson Italiana offers an important contribution to the early design process to optimize the system of valves, pipes, and silencers with regard to sizes and costs.</p>
<h3>BLOW-OFF OPERATIONS SERVICES</h3>
<p>To support plant blow-off operations Stopson Italiana provides a wide range of additional equipment and services:</p>
<p><strong>Engineering Services:</strong></p>
<ul>
<li>Hydraulic Engineering</li>
<li>Instruction and Procedures</li>
<li>Temporary Piping and Support Design</li>
<li>Final Report</li>
</ul>
<p><strong>Equipment – Sales and Rental Services:</strong></p>
<ul>
<li>Blow off silencers</li>
<li>Manual/Pneumatic Target Plate Holder</li>
<li>Target Plates</li>
<li>Valves</li>
<li>Pumps</li>
<li>Accessories</li>
</ul>
<p><strong>On-site Services:</strong></p>
<ul>
<li>Supervision</li>
<li>Consulting Services</li>
<li>Engineering</li>
<li>Representation</li>
</ul>
<p>Stopson Italiana’s extensive knowledge and experience providing A-Z soundproofing solutions to industrial facilities since 1965, ensure the supply of comprehensive acoustical solutions in support of meeting customer mandatory requirements and their soundproofing objectives, being temporary or permanent.</p>
<p>&nbsp;</p>
</div>
<p style="text-align: center;"><strong>CONTACT US!</strong></p>
<p>[contact-form-7 id=&#8221;803&#8243; title=&#8221;Contact us&#8221;]</p>
</div>
</div>
</div>
</div>
</div><p>The post <a href="https://stopson.it/en/blow-off-rental-service-now-available-at-stopson-italiana/">Blow-off Rental Service now available at Stopson Italiana</a> first appeared on <a href="https://stopson.it/en/">Stopson Italiana</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Stopson Italiana delivered Blow-Off Services to 2 Power plant in Egypt</title>
		<link>https://stopson.it/en/stopson-italiana-delivered-blow-off-services-to-2-ccpp-in-egypt/</link>
		
		<dc:creator><![CDATA[giango_admin]]></dc:creator>
		<pubDate>Tue, 18 Dec 2018 12:30:16 +0000</pubDate>
				<category><![CDATA[Projects]]></category>
		<category><![CDATA[Blow-off Silencers]]></category>
		<category><![CDATA[CCPP]]></category>
		<category><![CDATA[Industrial Silencers]]></category>
		<category><![CDATA[industrial silencers provider italy]]></category>
		<category><![CDATA[New Assiut]]></category>
		<category><![CDATA[Silencers]]></category>
		<category><![CDATA[Steam Blow-off]]></category>
		<category><![CDATA[Stopson Italiana]]></category>
		<category><![CDATA[West Damietta]]></category>
		<guid isPermaLink="false">https://stopson.it/2018/12/18/stopson-italiana-delivered-blow-off-services-to-2-ccpp-in-egypt/</guid>

					<description><![CDATA[<p>Blow-off Equipment, including Silencers, and Supervision from Stopson Italiana supported New Assiut and West Damietta Single to Combined Cycle Power Plants conversion in 2018 Stopson Italiana has successfully completed the supply of steam blow-off silencers and cleaning equipment, including pumps, valves, spectacle flanges, instrumentation and pneumatic target plates system, and provision of supervision services for [&#8230;]</p>
<p>The post <a href="https://stopson.it/en/stopson-italiana-delivered-blow-off-services-to-2-ccpp-in-egypt/">Stopson Italiana delivered Blow-Off Services to 2 Power plant in Egypt</a> first appeared on <a href="https://stopson.it/en/">Stopson Italiana</a>.</p>]]></description>
										<content:encoded><![CDATA[<h3><em>Blow-off Equipment, including Silencers, and Supervision from Stopson Italiana supported New Assiut and West Damietta Single to Combined Cycle Power Plants conversion in 2018</em></h3>
<p>Stopson Italiana has successfully completed the supply of steam blow-off silencers and cleaning equipment, including pumps, valves, spectacle flanges, instrumentation and pneumatic target plates system, and provision of supervision services for the blow-off operations of two Combined Cycle Power Plants (CCPP) performed in parallel.</p>
<p><img fetchpriority="high" decoding="async" class="size-medium wp-image-3857 alignleft" src="https://stopson.it/wp-content/uploads/2025/03/IMG_9605-225x300.jpg" alt="" width="225" height="300" /> The 230 t/h capacity silencers are equipped with 16 bara design pressure diffuser in a carbon steel casing 6 meters high with 2.5 meters diameter, capable to achieve a residual sound pressure level of 90 dB(A) at 3 m from equipment. Stopson Italiana’s blow-off silencers are based on a combined reactive and absorptive principle for noise reduction: the gases expand to atmospheric pressure through an horizontal large-holes perforated diffuser, providing a first step in attenuation while allowing any debris to flow out, then evolves into a sound-absorbing lining section to further contribute to reach required noise residual level.</p>
<p>The 1 GW New Assiut plant and 500 MW West Damietta plant have gone through a substantial upgrade with the addition of steam turbine modules recovering heat from existing Gas Turbines. This 750 MW addition over the two plants will take the total capacity to 2.25 GW, further contributing to helping meet the increasing demand for power in the country.</p>
<p>&nbsp;</p>
<p>Stopson Italiana’s offering for plant <strong><span style="text-decoration: underline;">Blow-off cleaning</span></strong> does include a various range of products and services:</p>
<ul>
<li><em>Engineering for Blow-off</em></li>
<li><em>Blow silencers</em></li>
<li><em>Steam blow flange</em></li>
<li><em>Spectacle flanges with gaskets</em></li>
<li><em>Demi water pumps</em></li>
<li><em>Gate and globe valves</em></li>
<li><em>Thermocouples</em></li>
<li><em>Temperature and Pressure transmitters</em></li>
<li><em>Pneumatic target plates inserters</em></li>
<li><em>Installation</em></li>
<li><em>Blow-off Supervision</em></li>
</ul><p>The post <a href="https://stopson.it/en/stopson-italiana-delivered-blow-off-services-to-2-ccpp-in-egypt/">Stopson Italiana delivered Blow-Off Services to 2 Power plant in Egypt</a> first appeared on <a href="https://stopson.it/en/">Stopson Italiana</a>.</p>]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
